Product Features
Using diffused silicon sensors or metal capacitive sensors, with 0.1% high precision, 10:1 wide range ratio, high stability, and high reliability,
Equipped with HART communication function, it has an intrinsic safety, explosion-proof, and high static pressure product series, and can be matched with special material isolation diaphragms, suitable for
Measure differential pressure under high temperature, high pressure, and strong corrosion conditions.
working principle
The medium pressure acts on the metal isolation corrugated membrane and is transmitted to the sensitive element β chamber through the intermediate silicone oil (see figure), which is sensitive
The measuring diaphragm of the component senses differential pressure to form a capacitance change, and the differential pressure and differential capacitance are in a linear state
The measurement circuit amplifies the differential pressure capacitance and converts it into a standard current signal output.
![]()
Technical Specifications
·Measurement range
Minimum measurement range (0-150) Pa; Maximum measurement range (0-2) MPa
·Measurement accuracy
The comprehensive error (including linearity, repeatability, and hysteresis) is better than 0.1%
1: 1~5:1 range ratio: 0.1% set range,
5: 1~10:1 range ratio: (0.05%+0.01% × TD)% set range
·Long term stability
Exceeding 0.15% F.s annually
·Allowable medium temperature
(-40~110)℃
·Allow ambient temperature
(-40~85)℃
·Allow storage temperature
(-40~85)℃
·Temperature influence
Relative to the standard range of 25 ℃≤± 0.4%
·Sensors allow
Working static pressure
Unidirectional and bidirectional maximum allowable static pressure PN13MPa
·Temperature influence
Under 100% condition, the impact is ≤ 0.25%
·Damping
0~40S continuously adjustable
·Anti vibration
2g 1000HZ ±0.05%g
·Impact resistance
50g 11mesc
·Electromagnetic compatibility characteristics
Compliant with IEC801 standard
·Load characteristics
Corresponding to power supply voltage impedance of 50 Ω~1000 Ω
·Sensors allow for overvoltage
3 times the standard range pressure
·Sensor range ratio
10: 1. Continuously adjustable zero point with 100% reverse migration capability
·Signal output
4-20mA linear output two-wire system with HART communication protocol
4-20mA square root output two-wire system with HART communication protocol
·Start time
3S without preheating required
·Power supply
12V~45VDC
·Power supply impact
≤ 0.005% V of output range
·Electrical connection
M4 screw grounding terminal suitable for 0.5~1.5mm ² with cable sealing shell suitable for outer diameter 6~8mm
·Process Connection
1/4NPT internal thread pressure pipe connection, M10 internal hole thread installation bracket connection
·Contact with medium
Sensor Ripple Diaphragm: Stainless Steel 316, Hastelloy C
Partial materials
Sensor sealing ring: Fluororubber EPDMPTFE, Kalrez
Elliptical flange: stainless steel 316; Hastelloy C
·Non contact with the medium
Shell: Die cast aluminum strip with epoxy resin coating
Partial materials
Nameplate: Stainless steel 304; Intermediate liquid silicone oil or anaerobic oil in sensors
Fastener: Stainless steel
·On site display
LCD 3 1/2 digital display
·Protection level
IP66
·Weight
About 1kg
·Explosion proof grade
Explosion proof Ex d Ⅱ C T5; Intrinsically safe Ex ia Ⅱ C T5
·Allow environmental humidity
100%RH
Exterior structure
load characteristic
R - allowable load resistance (Ω), U - power supply (V)
electrical connection
M screw grounding terminal is suitable for 0.5-2mm ² wires, M20 × 1.5 internal thread cable entry hole, with cable sealing sleeve for cables with outer diameter of 6-8mmInstrument installation
Wall mounted installation, b、 Vertical installation of pipelines, c、 Horizontal installation of pipelines
Order Selection Table