メール
wangguijiang@bjguancheng.com
-
電話番号
18513000801
-
アドレス
Room 104, Building C, Hongxianghong Enterprise Incubation Base, Beiqijia Town, Changping District, Beijing
Beijing Guancheng Measurement Technology Co., Ltd
wangguijiang@bjguancheng.com
18513000801
Room 104, Building C, Hongxianghong Enterprise Incubation Base, Beiqijia Town, Changping District, Beijing
Product Features
The PMC131 pressure transmitter adopts imported ceramic sensors or imported silicon piezoresistive sensors. PMC131 ceramic sensor is composed of
96% or 99% alumina ceramic film forms a flat capacitor structure. The medium pressure of the sensor directly acts on the ceramic
The sensor diaphragm causes displacement of the measuring diaphragm. Normal pressure causes the measuring diaphragm to deviate by 0.025mm. Under overpressure conditions
Only offset the measuring membrane by 0.1mm. At this point, the measuring membrane is attached to the ceramic bracket to avoid damage to the sensor
The capacitance generated by the displacement of the measuring film is detected by the electronic components directly connected to it, amplified and converted into a standard signal
Output; PMC13A and PMC13B silicon piezoresistive sensors are precision sensors made by vacuum diffusing semiconductors on a silicon substrate
Dense resistance strain bridge. It is separated from the detected medium by a layer of stainless steel corrugated sheet, and is transmitted through an intermediate liquid
To a strain bridge, the change in bridge resistance causes the bridge to lose balance and output a series of voltage signals proportional to the pressure P. pass
Signal amplification, circuit conversion standard electronic signal output.
Technical Specifications
·Measurement range
Relative pressure: PMC131 minimum measurement range: 0-0.5kPa maximum measurement range: 0-2MPa
The minimum measurement range of PMC131A is 0-2kPa; Maximum measurement range 0-4MPa
The minimum measurement range of PMC131B is 0-4MPa; Maximum measurement range 0-60MPa
Negative relative pressure: PMC131 minimum measurement range -0.5~0kPa; Maximum measurement range -0.1~2MPa
The minimum measurement range of PMC131A is -2~2kPa; Maximum measurement range -0.1~4MPa
The minimum measurement range of PMC131B is -0.1 to 4MPa; Maximum measurement range -0.1~0MPa
Absolute pressure: PMC131 has a minimum measurement range of 0-2kPa; Maximum measurement range 0-2MPa
The minimum measurement range of PMC131A is 0-15kPa; Maximum measurement range 0-4MPa
·Measurement accuracy
0.5% FS, 0.2% FS (including linearity, hysteresis, and repeatability). )
The measurement accuracy is limited to 0.5% FS when the range is below 2kPa
·Long term stability
Annual ≤ ± 0.1% FS
·Allowable working temperature
Allowable ambient temperature: -40 ℃ to+85 ℃; Allowable medium temperature: -40 ℃ to+120 ℃;
Allowable storage temperature: -40 ℃ to+80 ℃
·Temperature influence
0.2% - Compensation temperature -20 ℃~+80 ℃ full temperature range impact ≤± 1%
0.5% - precision compensation temperature -20 ℃ to+80 ℃, with a total temperature range impact of ≤± 1%;
Special requirements agreed upon
·Sensor type
PMC131- Ceramic Sensor; PMC136A - Low voltage type of silicon piezoresistive sensor;
PMC131B - High voltage type of silicon piezoresistive sensor;
·Signal output
(4-20) mA analog type (two-wire system); Or special requirements agreed upon
(4-20) mA intelligent type with HART communication protocol (two-wire system);
·Electromagnetic compatibility resistance
Interference radiation complies with EN50081-1; Anti interference complies with EN50082-2;
·Interference
Field strength of 10V/m complies with NAMUR industrial standards
·Working power supply
(4-20) mA output type (12-30) V DC
·Process Connection
PMC131: External thread M20 × 1.5, G1/2, 1/2NPT, G1 1/2 or special requirements agreed upon
PMC1131: External thread M20 × 1.5 G1/2、1/2NPT、 Or special requirements agreed upon
·Electrical connection
Right angled elbow socket type (Hosman plug PG 9, cable outer diameter 6mm~8mm);
Overall cable type; Integrated air conducting cable type (suitable for IP68); Or special requirements agreed upon
·Working voltage
18-35VDC analog output
·Load resistance
Current output RLMAX [Ω] ≤ (US-12V/0.02A) (LMAX [Ω] ≤ 600 Ω at 24V,
RLMAX [Ω] ≤ 900 Ω at 30V) voltage output RLmin [Ω] ≥ 5 k Ω
·Contact with medium
PMC131 sensor material: 96% or 99% alumina ceramic;
Partial materials
Process connectors: Stainless steel 304 or special requirements as agreed upon
PMC131A sensor corrugated isolation film”Stainless steel 316L sheet
Process connectors: Stainless steel 304 or special requirements as agreed upon
PMC131B sensor corrugated isolation diaphragm: stainless steel 316L
Process connectors: Stainless steel 304 or special requirements as agreed upon
·Sealing ring material
PMC131: Fluororubber or specific requirements; PMC1131: Welding structure without sealing ring;
PMC135B: Nitrile rubber or specific requirements
·Shell material
Stainless Steel 304
·Protection level
Right angle elbow IP65; Overall cable IP65; Integrated air conducting cable IP68 (according to
The customer requires deep water production; Or special requirements agreed upon
·Allow environmental humidity
98%RH
Exterior structure
![]()
When installing instruments, it is forbidden to rotate the right angle elbow with hands or toolsa. Overall cable type; L≈62mm; b. Right angled elbow type; L≈51mm
![]()
C External thread M20X1.5 or G1/2 small hole d. External thread M20X1.5 or G1/2 large hole e. External thread 1/2NPT small hole
![]()
f. External thread 1/2NPT internal thread 1/4NPT type g. External thread G11/2 flat film type
electrical connection
Order Selection TableIn environments with strong interference, in order to ensure the normal operation of instruments, they should be reliably grounded according to relevant instrument grounding technical specifications!